Friday, September 27, 2013
activity is shown by NNP 824 against both definitely replicating
transfection of HeLa Empty cells with an siRNA share targeting genes needed for cell survival resulted in a substantial increase in NucView488 signal compared to a no siRNA handle or transfection with an un-targeted siRNA ; in HeLa Crizotinib Bcl XL cells, the quantified NucView488 signal was considerably reduced compared to HeLa Empty cells. Altogether, our validate the new technique we have developed, because we could reliably monitor and quantify apoptosis induced by small molecules or RNA interference over time, and its inhibition by caspase inhibition or by overexpression of the anti-apoptotic Bcl XL protein. As opposed to past uses of the DNV substrate, we show our method allows monitoring of apoptosis for exactly the same cell population at multiple time points.
Of note, the fact that our method may be applied to either track apoptosis induced by a small particle or by knockdown of gene expression illustrates its great flexibility. For further validation, we sought to try our method in a different cell system; we used for this purpose the well described NSCLC cell lines H3255 and H203021. We could precisely Metastasis monitor the actual time kinetics of caspase activation caused by Erlotinib inside the Erlotinib sensitive cell line H3255. Needlessly to say, the powerful caspase activation induced by Erlotinib within this cell line was dose and time dependent. On the other hand, only low levels of caspase activation could be discovered in the Erlotinib refractory H2030 cell line anytime level or tested concentration.
These clearly examine our method and show its flexibility, Imatinib in that we're able to easily use our recently developed assay with various cell lines without any prior cell engineering or any dedicated optimization for the new lines. In addition, our live, realtime process allowed us to just take multiple photos of the cells through the same experiment. This result is essential as it demonstrates that our method can detect early along with late inducers of apoptosis in the same screen. Furthermore, our technique enables a higher throughput screen to be performed without compromising plate to plate variability. Based on our experience and in accordance with simulations using the POLARA? Arrangement software, we calculate that the throughput of well plates weekly can be achieved by plates.
This estimation is based on a fully-automated display with three read-outs every 24h over a course of 72h, where all plates are read at very same intervals of 24h. This throughput permits the screening of roughly 35,000 compounds weekly. We have done such a display with a total of 28 plates and we will be publishing the in a manuscript shortly. In conclusion, our method meets each of the requirements for a live assay aimed at quantifying apoptosis in high density format.
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment